868 research outputs found

    Altered expression of transforming growth factor-βs in chronic renal rejection

    Get PDF
    Altered expression of transforming growth factor-βs in chronic renal rejection. We examined the altered expression of transforming growth factor-βs in chronic renal rejection in humans, including transforming growth factor beta-1 (TGF-β1), TGF-β2, TGF-β3 and their receptors, transforming growth factor beta receptor type I (TβR-I) and TβR-II. Using Northern blot analysis and immunohistochemistry, 10 specimens of chronically rejected and 8 normal kidney samples were analyzed. By Northern blot analysis the expression of mRNA encoding TGF-β1, TGF-β2, TGF-β3 (P < 0.02), TβR-I and TβR-II (P < 0.02) was decreased in chronically rejected renal cortex samples, compared to normal controls. Immunohistochemical analysis of the normal renal cortex showed strong immunostaining for TGF-β1 and TGF-β3, and mild immunostaining for TGF-β2 in the proximal and distal tubulointerstitium, but no signal for any of the TGF-β isoforms in the glomeruli or in the cortical vessels. In sharp contrast, the glomeruli and the cortical vessels of the rejected kidney specimens exhibited strong immunostaining for TGF-β1 and TGF-β3, whereas the tubules revealed a decrease in immunoreactivity. TβRI and TβRII immunostaining showed similar changes as observed with TGF-β1 and TGF-β3 antibodies. There was a concomitant increase in B-cell accumulation in the glomeruli, while T-cells and macrophages were diffusely abundant in the rejected samples. Since TGF-βs are potent inducers of extracellular matrix proteins and have been shown to be involved in fibrotic disease, the increase in TGF-β1 and TGF-β3 immunoreactivity in the glomeruli suggests that there is a redistribution in TGF-β expression in chronic renal allograft rejection. Together with changes affected by B-cell mediated immunity, the above alterations might contribute to the histopathological changes that occur in this disorder, such as intimal fibrosis, arteriosclerosis and glomerular and tubular sclerosis

    Idiopathic Palmar Fasciitis with Polyarthritis Syndrome

    Get PDF
    A 31-yr-old Korean woman was presented with 4-month history of bilateral hand swelling and stiffness. On clinical examination, she had a painful synovitis of both hands, wrists, knees and ankles. The radiologic and histological examinations confirmed it with palmar fasciitis and polyarthritis syndrome (PFPAS). PFPAS is an uncommon disorder characterized by progressive flexion contractures of both hands, inflammatory fasciitiis, fibrosis, and a generalized inflammatory arthritis. Although most reported cases of PFPAS have been associated with various malignancies, our patient have not been associated with malignancy during 24 months follow up period from her first symptom onset. Her symptoms were improved with moderate dose of corticosteroid and she is currently taking prednisone 5 mg daily without any evidence for internal malignancy. We present here in a young Korean patient with idiopathic PFPAS who was successfully treated with administration of corticosteroid

    Book reviews

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/42841/1/10734_2004_Article_BF00129796.pd

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    The GJ 436 System: Directly Determined Astrophysical Parameters of an M-Dwarf and Implications for the Transiting Hot Neptune

    Get PDF
    The late-type dwarf GJ 436 is known to host a transiting Neptune-mass planet in a 2.6-day orbit. We present results of our interferometric measurements to directly determine the stellar diameter (R=0.455±0.018RR_{\star} = 0.455 \pm 0.018 R_{\odot}) and effective temperature (TEFF=3416±54T_{\rm EFF} = 3416 \pm 54 K). We combine our stellar parameters with literature time-series data, which allows us to calculate physical and orbital system parameters, including GJ 436's stellar mass (M=0.5070.062+0.071MM_{\star} = 0.507^{+ 0.071}_{- 0.062} M_{\odot}) and density (ρ=5.370.27+0.30ρ\rho_* = 5.37^{+ 0.30}_{- 0.27} \rho_\odot), planetary radius (Rp=0.3690.015+0.015RJupiterR_{p} = 0.369^{+ 0.015}_{- 0.015} R_{Jupiter}), planetary mass (Mp=0.0780.008+0.007MJupiterM_{p} = 0.078^{+ 0.007}_{- 0.008} M_{Jupiter}), implying a mean planetary density of ρp=1.550.10+0.12ρJupiter\rho_{p} = 1.55^{+ 0.12}_{- 0.10} \rho_{Jupiter}. These values are generally in good agreement with previous literature estimates based on assumed stellar mass and photometric light curve fitting. Finally, we examine the expected phase curves of the hot Neptune GJ 436b, based on various assumptions concerning the efficiency of energy redistribution in the planetary atmosphere, and find that it could be constrained with {\it Spitzer} monitoring observations.Comment: 10 pages, 4 tables, 9 figures; accepted for publication in ApJ; incorporated referee's comments and associated change

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented
    corecore